- Circuit Breakers[6]
- Wall Switches[6]
- Contactors[6]
- Power Distribution Equipment[6]
- Voltage Regulators/Stabilizers[6]
- Electrical Plugs & Sockets[6]
- Relays[6]
- Power Accessories[6]
- Switching Power Supply[6]
- Fuses[6]
- Push Button Switches[6]
- Transformers[6]
- Instrument Parts & Accessories[1]
- Energy Meters[4]
- Current Meters[2]
- Temperature Instruments[1]
- Other Electrical Equipment[6]
- Insulation Materials & Elements[1]
- Terminals[3]
- Terminal Blocks[1]
- Capacitors[6]
- Other Lights & Lighting Products[1]
- Contact Person : Mr. Ye Victor
- Company Name : Changcheng Electrical Equipment Group Zhejiang Imp. & Exp. Co., Ltd.
- Tel : 86-577-61989999
- Fax : 86-577-61891122
- Address : Zhejiang,Yueqing,Changcheng High-Tech Industrial Zone,North Baixiang, Yueqing ,Zhejiang,325603 P.R.China
- Country/Region : China
- Zip : 325603
Low voltage self-healing shunt capacitor YC111
CNC Low Voltage Self-healing Shunt Power Capacitor YC111
Features:
Cylinder Type, small volume, light weight, convenient installation,
low loss, little radiation and low temperature rise, excellent self-healing performanceSafety: No oil leakage, no-toxic and environment protectionCertificate:ISO9001, TSEOEM accepted.
Working Condition:Altitude: lower than 3000mAmbient temperature: -25~55 degree CelsiusHumidity: under 95%After the power cut off, reputing when make sure the remain
voltage is smaller than 10% of the rated voltage, usually this
time is 200s, so the controller you use should has the function
of time delay for reputing after cut off.
Main Technical Characteristics:Standard:IEC60831-1996 GB/T12747.1-2004
Rated voltage:0.23KV,0.4KV,0.415KV,0.45KV,0.525KV and so on.Rated capacity:0.5~30KvarMax allowable voltage: Rated voltage 110%Max allowable current: Rated voltage 130%
ConstructionDielectric: Polypropylene filmdry typeWave cutExtruded round aluminum can with threadedProtection:IP20Features
Three phase,delta connected.With discharge resistorSelf-healing technology,overpressure disconnectorNaturally air cooled(or forced air cooling)Indoor mountingfile#E307252
Technical characteristics
Capacitance (KVAR) | Size (φ×L)mm | Bolt (mm) | Bolt (mm) |
0.5 | 60×150 | M12×15 |
|
1 | 60×150 | M12×15 |
|
2 | 60×150 | M12×15 |
|
3 | 60×150 | M12×15 |
|
5 | 60×150 | M12×15 |
|
7.5 | 60×225 | M12×15 |
|
8 | 60×225 | M12×15 |
|
10 | 60×265 | M12×15 |
|
12.5 | 70×225 | M12×15 |
|
15 | 70×265 | M12×15 |
|
16 | 85×240 | M12×15 |
|
18 | 85×285 | M12×15 |
|
20 | 85×285 | M12×15 |
|
25 | 85×285 | M12×15 |
|
30 | 85×355 | M12×15 |
|
Optional Voltage: 220VAC 230VAC 380VAC 400VAC 415VAC440VAC 480VAC 525VAC 690VAC | |||
Optional Frequency:50Hz/60Hz | |||
Single phase or three phase on requested |
Technical data and specification
Charateristics | |
Rated capacitance CRand QR | According to specification table |
Tolerance | -5/+10% |
Connection | D(Delta) |
Rated voltage VR | According to specification table |
Rated frequency fR | 50/60Hz |
Maximum ratings(to IEC 60831) | |
Maximunm permissible voltage Vmax | VR+10%(up to 8 h daily)VR+15%(up to 30 min daily)VR+20%(up to 5 min daily)VR+30%(up to 1 min daily) |
Maximum permissible current Imax | Up to 1.3×IRincl.combined effects of harmonics,over voltages and capacitance) |
Maximum transient inrush current | Up to 200×IR |
Power dissipation (dielectric) | <0.2 W/kvar |
Power dissipation(excluding discharge resistors) | <0.45 W/kvar |
Test data(accord. to IEC 60831) | |
AC test voltage terminal-to-terminal | 2.15×VR,2s |
Insulation voltage between terminalsand container | 3000V AC, 10s |
Dissipation factor tanδat 100Hz | ≤1.0×10-3 |
Safety | |
Mechanical | Overpressure disconnector |
Max. | (AFC:10000) |
Discharge | ≤3min (75V) |